Shanghai Weiye Optic Fiber Communication Equipment Co., Ltd. supplies equipment for producing rollable formats used in optical-fiber manufacturing. Buyers can compare the capacity of this setup against their intended product range because it is designed for 12- and 16-fiber ribbons. Its split-type construction may also affect factory space and installation requirements.




For this specific production line, the specified construction speed is 600 m/min. The process combines fiber pay-off, gathering and guiding, intermittent resin dispensing, UV-LED curing, visual monitoring, capstan pulling, and take-up. The full process is important to evaluate, not just the stated speed.

Before purchasing, check factory utilities, reel requirements, available floor space, and installation conditions. Request the supplier’s documentation package and verify that the system matches your cable design and operating needs. Early planning for these details can minimize setup delays and make startup smoother.

Main Takeaways

  • Designed for rollable 12- and 16-fiber formats.
  • Specified equipment speed: 600 m/min.
  • Uses a split-type construction.
  • Includes curing, monitoring, pulling, and take-up stages.
  • Before purchasing, verify utilities, reels, installation requirements, and supplier documentation.

Intermittent Bonded Ribbon Production LineIntermittent Bonded Ribbon Production Line

Examine The Intermittent Bonded Ribbon Production Line

To create rollable IBR formats, three mold groups arrange fibers for the application of small adhesive dots. Mold position is adjustable by operators from 0 to 15 mm, helping produce consistent spacing and form.

Make Rollable Fiber Ribbons Using Precision Bonding

The machine is fed by a 16-spool pay-off, and guide rollers with U-shaped grooves help maintain the organization of each strand. Steady contact during processing is supported by the rollers’ hard-anodized surfaces. For 12F and 16F layouts, the adjustable valve setup uses 5+5+1 valves for 12 fibers or 5+5+5 for 16. Ask the supplier to verify tension control settings that suit your particular cable design.

Support 12- And 16-Fiber Configurations At Speeds Up To 600 m/min

The stated construction speed is up to 600 m/min. The listed reel dimensions, Φ236 mm × Φ25.4 mm × 108 mm and Φ267 mm × Φ25.4 mm × 180 mm, correspond to pay-off reel options holding 25.2 km or 50.4 km of fiber. T-type and fiber-optic take-up reels are also available for this system. Assess whether reel capacity suits your operating needs and anticipated changeover time.

Review The Production Line’s Key Equipment And Controls

Tension, resin placement, and UV exposure must work together to deliver reliable output. Operators can use the system to align settings with the needs of their cable design and fiber ribbon.

Manage Fiber Tension, Resin Dispensing, And UV-LED Curing Together

Every pay-off unit uses electro-pneumatic adjustment. Through the interface, operators set adhesive-dot spacing and counts while dispensers work individually or in linked groups.

Three pre-curing ovens support the mold groups ahead of UV-LED post-curing. Verify resin compatibility and operating conditions with the supplier.

The Siemens PLC and touchscreen show lamp current and oven temperature, generate alarms, and support preset lengths. Before purchase, review cabinet requirements and power supply needs.

Stage Specification Buyer check
Fiber tension Pay-off tension: 0.4 to 2 N with ±0.02 N; capstan tension: 50 to 500 g with ±5 g accuracy Match settings to cable needs
Resin dispensing Individually operated or linked units with adjustable adhesive-dot spacing and count Check interface configuration
UV-LED curing Three pre-curing ovens rated 800 W each; one post-curing oven rated 6 kW; 395 nm ± 3 nm; at least 85% cure during stable, high-speed operation Confirm resin compatibility
Monitoring Siemens S7-1200 or S7-1500 PLC; 10.4-inch touchscreen; real-time lamp current and oven temperature, alarms, preset lengths Verify cabinet and power supply requirements

Prepare Line Configuration, Installation, And Operating Conditions

Before the machine is delivered, prepare a dedicated operating area. The optical fibre system requires an enclosed, clean, dry, and draft-free environment. Keep the temperature from 15°C to 25°C, with humidity at or below 85%. These conditions help safeguard fiber equipment and maintain precision during operation.

With your facilities team, check site utilities, available electrical capacity, cabinet space, and cable design. Nitrogen at 7 bar with 99.99% purity and compressed air at 6 bar are specified for the system. The electrical supply must be three-phase, five-wire, and 380 V ±10%.

  • Reserve room for the cabinet, components, resin, and access to service parts. Before starting the line, check the temperature settings and tension control.
  • Plan around the specified reel dimensions of Φ410 mm × Φ50.8 mm × 391 mm. The take-up unit supports reels weighing up to 30 kg.
  • Include the main power feed-in cable in your site plan. Connection cables and cable trays are not included with the equipment.

Before ordering, verify the supply scope, reel types, and installation requirements. This assessment can shorten setup time and help prevent later delays. Ask the supplier to verify settings for your fiber and cable design, including lamp accuracy and operating conditions. A clear plan helps the production system begin operating more smoothly.

Request Pricing For A Ribbon Production Solution Tailored To Your Needs

Manufacturers seeking rollable 12- or 16-fiber formats can assess this line at its stated speed of 600 m/min. Share details of your fiber layout, output targets, cable requirements, reel preferences, and factory conditions to request a quotation.

Confirm that the proposed system includes the 16-spool pay-off, UV-LED curing arrangement, take-up capacity, and relevant options. Examine the included components, dispensing-head options, unit functions, and cable design prior to ordering.

Listed documents include operating and maintenance manuals, a general layout drawing, electrical schematics, and a wear-parts list. These documents can help assess setup time and ongoing service needs.

Contact Shanghai Weiye Optic Fiber Communication Equipment Co., Ltd. to request pricing and configuration details that suit your output plan and site utilities. Verify the supply scope and replacement parts before purchase.